ROC INC - Metal Wall and Roof Systems

(717) 823-6492

Architectural Roof Panels

Here you will find drawings, specifications, descriptions and PDF documents for Architectural roof panels from ROC INC.

Detail

Amp-Lok

Description

Prestige structural standing seam roof system

The Prestige panel shall have a coverage of 12", 14", 16", or 18". Seams shall be 2" high. Roof panels shall use a two-piece roof clip allowing for thermal movement of the panel system. The panel shall have a factory-applied mastic and be mechanically seamed with a field operated electric seaming machine provided by the manufacturer. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves. Panels have 1" shadowlines as a standard.

Specifications

• Factory applied sealant is standard
• Mechanical seaming ensures weather-tightness
• 2 piece clip allows for thermal movement
• Standard widths: 16" and 18"
• Minimum roof slope: 1:12
• Shadow lines are standard
• Multiple UL90 ratings
• Can be factory or field curved - minimum 10 foot radius
• Panels can be tapered
• Can be installed over open framing or solid substrate
• Allowable loads are based on 1980 edition of AISI specifications.
• Deflection is limited to L/240 of span.
• Loads are based on spans of 3 or more.
• FY=50 ksi for steel panels.
• Uplift values based on attachment to 16 ga purlins with 2 # 10-16x1" SD ST screws.

 

PDF

Back to Top

Panel Detail

Thin Seam

Description

Thin Seam panel shall have a 1¾" seam height, a maximum seam ", and a seam spacing of 12", 14", 16", or 18" wide. Roof panels shall?width of use a two-piece roof clip allowing for thermal movement of the panel system. The standing seam shall have a built in capillary break with the option of a factory applied sealant in the female leg. Concealed one piece roof clip will engage the panel seal allowing for unlimited thermal movement. The standing seam shall snap lock together without the use of or need for an electric seaming device. Roof panels shall be removable for replacement of damaged materials during and after installation is completed. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves.

Specifications

• Standard widths available: 16" and 18"
• Multiple UL90 ratings
• Minimum roof slope: 1:12
• Factory applied sealant is standard
• Stiffening ribs or shadow lines available for different aesthetic requirements
• Can be installed over open framing or solid substrates

PDF

 

 

Back to Top

Detail

Double-Lok

Description

Double Lock panel shall be formed as 1½" seam height with a seam spacing of 12", 16", or 20" on center. Roof panels shall use a two-piece roof clip allowing for thermal movement of the panel system. The panel shall be mechanically seamed with a field-operated, electric- seaming machine provided by the manufacturer. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves. The maximum panel length shall be 40' (consult with factory for longer lengths). his panel shall be installed over a solid deck only.

Specifications

• Designed for commercial and residential applications
• Panels can be tapered
• An economical mechanically seamed roof panel
• 2-piece clip allows for unlimited thermal movement
• Provides a traditional 5-ply double lock standing-seam
• Requires installation over solid substrate
• Minimum roof slope: 3:12
• 4 widths available: 12", 16", 18" and 20"

PDF

 

 

Back to Top

Panel Detail

Grand Curve

Description.

Engineered for durability and flexibility, Grand Curve handles the gentle slopes and changing lines of twenty-first century buildings with ease. Plus two different cap options provide two distinctly different appearances for maximum curb appeal.

Specifications

• Available in G90 Steel, Galvalume with acrylic coating, Aluminum or Copper substrates
• Panels can be curved to a 15' minimum radius
• UL 90 rated on narrow cap system
• 1 3/4" or 2" depth
• Optional wide batten or narrow cap design
• Curved battens/caps to exact dimensions
• Clips provide unlimited thermal movement
• ASTM E1592 test reports for both wide and narrow batten systems
• Custom panel widths & coverage options available, please inquire

PDF Files: Grand Curve N, Grand Curve W

 

 

Back to Top

Panel Detail

Slim Seam

Description

The Slim Seam panel shall have a coverage of 12" or 16". Seams shall be 1½" high. Roof panels shall use a one-piece roof clip allowing for unlimited thermal movement of the panel system. The panel shall have a factory applied mastic and be seamed by snapping together the integral seam. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves.

Specifications

• An economical, high-performing standing-seam roof system that's ideal for architectural, commercial and residential applications
• Panels can be tapered
• Unique stainless steel clip allows unrestricted thermal movement
• Installer friendly—snap-together side joint requires no mechanical seaming
• Factory formed panels, with factory-applied sealant
• Multiple UL ratings for both steel and aluminum substrates
• UL Class A fire rated • Usually installed over solid substrate but may be installed over open framing with 3' O.C. maximum spacing
• Minimum roof slope: 1:12
• Available widths: 12" and 16"

 

Back to Top

Panel Detail

High Seam

Description

High Seam panel shall have a 1½" seam height with a maximum seam width of ¼" and a panel coverage of 12", 14", 16", 18", or 20". Roof panels shall use a one-piece roof clip allowing for thermal movement of the panel system. The panel shall snap lock together without the use or need of an electric seaming machine. Roof panels shall be removable for replacement of damaged materials during and after installation is completed. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves. Panels are available smooth or with 1" shadowlines.

Specifications

• Panel seams snap together—no mechanical seaming required
• Panels can be tapered
• One-piece clip allows unlimited thermal movement
• UL90 rating for installation over plywood substrate
• Optional shadow lines available
• Installation over solid substrate is required
• Minimum roof slope: 2:12
• Standard widths: 16" and 18"

 

Back to Top

Detail

Snap-On Batten

Description

The Snap-on-Batten panel shall have a seam height of 1½" and spaced 12", 14", 16", 18", or 20" o.c. The snap on batten cap will be 1½" wide by 1¾" tall. Roof panels shall use a one-piece roof clip allowing for thermal movement of the panel system.

Specifications

• Classic bold box batten look
• Concealed clip allows for thermal movement
• Panels can be tapered
• Requires solid substrate for installation
• Minimum roof slope: 3:12 • 4 widths available: 12", 16", 18" and 20"

PDF

 

 

Back to Top

Panel Detail

Snap-On Seam

Description

The Snap-on-Seam panels shall have a seams that are 1¾" tall (also available in 1" seam height) and spaced 12", 14", 16", 18", or 20" o.c. The panels are held in place with one-piece, concealed clips that permit thermal movement. A narrow seam cap will then snap over the seam and clips. This panel may be curved with a minimum radius of 5'. The panel seam leg will be shortened to enhance radius capabilities.

Specifications

• Ideal for roof applications requiring curved panels
• Concealed clip allows for thermal movement
• 1" Panel can be curved to a minimum radius of 5' 0"
• Panels can be tapered • Easily handles roof to fascia transitions
• Installation over solid substrate is required
• Minimum roof slope: 3:12
• 4 widths available: 12", 16", 18" and 20"

PDF

 

 

Back to Top

Panel Detail

Stand 'N Seam

Description

A high-performance, structural standing-seam roof system for the most demanding applications. Test reports confirm that Stand 'N Seam has the highest wind uplift resistance of any standing-seam panel available in the market. Unique one-piece stainless steel clip design does not fold into side joint of panel, allowing unrestricted thermal movement.

Specifications

• Side joints are double lock-seamed with electric seaming machine ensuring weathertightness
• Factory or field-formed by portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end-laps.
• Factory applied sealant is standard
• ASTM E1592 and Multiple UL90 ratings in both steel and aluminum for applications over open framing or solid substrates • Fully tested performance for air and water infiltration
• Multiple UL fire resistant assemblies available and Class A fire rated
• Minimum roof slope: 1/2:12
• Available widths: 12" and 16"

PDF

 

 

Back to Top

Panel Detail

T-Rib

Description

The T-Rib panel shall have a width of 12", 14", 16", or 18" wide. Seams shall be 2½" high with a ½" top flange angled at 90 degrees from the seam to facilitate the seaming of the panel and cap. The panels shall have 1/16" x 1" stiffening ribs in the pan of the panel. Roof panels shall use a one-piece roof clip allowing for thermal movement of the panel system. The panel shall have a factory applied mastic and be mechanically seamed with a field operated electric seaming machine provided by the manufacturer. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves. The maximum cap length shall be 30'.

Specifications

• A 21/2" high rib panel with excellent design flexibility
• Ease of installation for difficult hip, ridge, and valley conditions
• Mechanically seamed cap strip with factory- applied weatherstripping assures a weather-tight seam
• One-piece concealed clip allows for unlimited thermal movement
• Panels can be tapered
• Symmetrical design allows panels to be installed in either direction
• Multiple UL90 ratings for steel panels
• Can be installed over open framing or solid substrate
• Minimum roof slope: 1/2:12
• Standard widths: 16" and 18"

PDF

 

 

Back to Top

Panel Detail

4" Rib

Description

An industry standard—Ideal for heavy industrial and lagging applications

Specifications

• Available mill finish, clad or painted in .032", .040" and .050" aluminum
• Available in 24, 22 & 20 gauge steel, 32" coverage
• Panels can be curved
• Minimum slope for steel roofing applications is 21/2:12
• Standard lengths: 6'-45'
• 8" Rib available on an inquiry basis
• The allowable loads are based on 1986 AISI and 1986 Aluminum Association specifications.
• The allowable loads are based on stress only.
• The allowable loads for the steel load table may be increased by 1/3 for wind loading. The allowable loads have been increased for the aluminum load tables by 1/3 for wind loading. • The use of steel 4" Rib panels on roof pitches less than 2 1/2":12 (12°) is not recommended.
• The maximum individual panel length for steel 4" Rib on roofs in 32' due to thermal movement considerations.
• The use of aluminum 4" Rib panels on roofs is not recommended.

PDF

 

Back to Top

Detail

Corrugated

Description

Factory formed, prefinished, lappable, exposed fastener, structural ribbed metal roof and wall system, that has been pretested and certified by manufacturer to comply with specified requirements under installed conditions.

PDF

Back to Top

Detail

Deep Rib II

Description

The Deep Rib II panel shall have a coverage of 30" for steel and 40" for aluminum". Rib height shall be 2". Panels shall be directly fastened to the substrate. The panel shall have a overlapping sidelap feature.

Specifications

• Can be used for both wall and roof applications
• Available in 22 and 18 gauge steel
• Available in .032", .040" and .050" aluminum (43-7/8" panel with 40" coverage)

PDF

 

Back to Top

Panel Detail

Deep Rib IV

Description.

A bold rib design, perfect for horizontal and vertical applications. Large 4" deep ribs provide excellent strength and spanning capacity. Can be used inverted for roof applications. Minimum roof slope: 1:12. Excellent for applications with large spans between structural framing members. Standard lengths: 6'-45'

Specifications

• The Deep Rib IV panel shall have a coverage of 24". Rib height shall be 4".
• Panels shall be directly fastened to the substrate.
• The panel shall have a overlapping sidelap feature.

PDF

 

Back to Top

Panel Detail

Hefti-Rib

Description

A classic design with 7.2" rib spacing. Excellent strength and spanning capability. Excellent for both wall and roof applications.

Specifications

• Available in .032" and .040" aluminum
• Available in 24, 22, 20 and 18 gauge steel
• Panels can be curved
• Minimum slope for roofing applications is 2:12
• Standard lengths: 6'-45' • 36" wide weather coverage
• Diaphragm capacity per ICBO Evaluation Report

Back to Top

Panel Detail

IP Seam 3

Specifications

• Classic mechanical seamed trapezoidal panel design
• Designed for low slope industrial applications
• Ideal for high performance Pre-Engineered Metal Buildings
• 3" nominal seam height - 24" seam centers
• 180 and 360 degree seaming available
• Factory applied sealant standard
• Concealed clip allows for thermal movement
• Normally installed over open framed structures

Back to Top

Detail

IP Snap 3

Specifications

• Classic engineered snap-together trapezoidal panel design
• Designed for low slope industrial applications
• Ideal for Pre-Engineered Metal Buildings and Mini Storage Structures
• 3" nominal seam height - 24" seam centers
• Factory applied sealant standard
• Concealed clip allows for thermal movement
• Normally installed over open framed structures

PDF

 

Back to Top

Panel Detail

Mighti-Rib

Description

The Mighti-Rib PBR panel shall have a coverage of 36". Panels shall be directly fastened to the substrate. The panel shall have an overlapping sidelap feature.

Specifications

• Excellent for commercial and industrial applications
• 26 gauge full hard (80 ksi) steel
• Diaphragm capacity per ICBO Evaluation Report
• Standard lengths: 6'-45'
• PBR panels require a minimum slope of 1:12
• UL90 rating for PBR panels when attached to steel purlins
• Available unpainted or finished with high-performance Super Alurite® paint system

PDF

 

Back to Top

Panel Detail

V-Beam

Description

The V-Beam panel shall have a coverage of 32" for steel and 42 aluminum. Rib height shall be 1¾". Panels shall be directly fastened to the substrate. The panel shall have a overlapping sidelap feature.

Specifications

• Minimum slope for roofing applications is 2:12
• Available in .040" and .050" aluminum
• Excellent strength and spanning capability
• Diaphragm capacity per ICBO Evaluation Report
• Standard lengths: 6'-45'

PDF

 

Back to Top

 

 

Home | About ROC INC | Metal Wall and Roof Systems | Thin Panel Metal Wall Products | Thin Panel Metal Roof Products
Thin Panel Metal Wall and Roof Types
| Thin Panel Metal Wall and Roof Materials | Custom Fabrication | Sitemap | Contact ROC INC
2016 ROC INC All Rights Reserved